LB Agar (Miller) Plates
Ready-to-use 90 mm LB agar plates for routine cultivation of Escherichia coli, molecular cloning and maintenance of recombinant strains.
At a Glance
Intended Use
Ready-to-use 90 mm LB agar plates, Miller formulation, for the routine cultivation, subculture and maintenance of Escherichia coli and other non-fastidious bacteria, and for molecular cloning workflows.
For laboratory microbiological testing, quality control and research use only. Not intended for direct use in food, human or veterinary therapeutic applications, diagnosis, or consumption.
Principle
Tryptone supplies peptides and amino acids, and yeast extract supplies B vitamins, nucleotides and trace growth factors. Together they support rapid growth of E. coli without a defined carbohydrate, which is part of why the medium became standard for cloning: there is no fermentable sugar to acidify the plate or to interfere with inducible promoters.
Sodium chloride at 10 g/L maintains osmotic balance. This is the Miller formulation; the Lennox version of the same medium uses 5 g/L.
The medium contains no selective agent. Selection of plasmid-bearing cells depends on an antibiotic, which has to be incorporated into the molten agar before the plate is poured.
Formulation (g/L)
| Component | g/L |
|---|---|
| Agar | 15.00 |
| Tryptone | 10.00 |
| Sodium chloride | 10.00 |
| Yeast extract | 5.00 |
| Total | 40.00 |
Final pH 7.0 ± 0.2 at 25 °C. Miller formulation. Formulation may be adjusted to meet performance specifications.
Key Applications
Reading the Results
| Organism group | Typical appearance |
|---|---|
| Escherichia coli | Cream to off-white, smooth, convex colonies, 1–3 mm after 18–24 hours |
| Other non-fastidious bacteria | Growth; appearance varies by species, some pigmented |
| Yeasts and moulds | May grow on extended incubation |
Growth does not identify an organism or confirm a clone. Confirm transformants by colony PCR, restriction digestion or sequencing as appropriate.
Advantages & Considerations
- Ready to use: no weighing, autoclaving or pouring
- The standard medium for E. coli work, so results are comparable between laboratories
- No fermentable carbohydrate, so the plate does not acidify and inducible systems are unaffected
- Rapid growth: readable colonies after an overnight incubation
- Non-selective. Contaminating organisms will also grow, and plasmid selection is not possible without an antibiotic.
- Antibiotics cannot be added to a plate that has already set. Antibiotic plates must be made with the antibiotic in the melt.
- Pour-plate counts are not possible with a pre-poured plate. Use surface spread or streak inoculation.
- Growth rate and colony size vary between host strains.
Frequently Asked Questions
Are these plates Miller or Lennox?
Miller. The Miller formulation contains 10 g/L sodium chloride; the Lennox formulation contains 5 g/L. Miller is the more widely used of the two for routine E. coli work. Both give equivalent growth for most purposes; the lower-salt Lennox version is sometimes preferred where osmotic stress affects plasmid yield or protein expression.
Can I get these plates with ampicillin or kanamycin?
Not by adding antibiotic to a plate that has already set. Antibiotics must be added to the molten agar after autoclaving and before pouring. Contact us for antibiotic-containing plates made to your specified antibiotic and concentration.
What does LB stand for?
Lysogeny broth. Giuseppe Bertani formulated it in 1951 to study lysogeny in E. coli, and confirmed in 2004 that the initials were never intended to mean Luria-Bertani, Luria broth or Lennox broth.
Can I do a pour-plate count with these plates?
No. A pour-plate count requires mixing the sample into molten agar, which is not possible with a plate that has already set. Use surface spread or streak inoculation, or use the dehydrated medium if your method specifies a pour plate.
How long will plates keep once I open the sleeve?
Return unused plates to the refrigerator in the sleeve and use them well inside the expiry date. Plates left out at room temperature dry at the edges within a few days, and a dried plate gives poor and uneven growth.
Technical Specifications
| Catalogue No. | AS-704 |
| Also known as | LB Agar; Lysogeny Broth Agar; Luria-Bertani Agar; LB Agar Miller |
| Format | Ready-to-use poured plates, 90 mm, flat agar surface |
| Fill volume | 20 ± 1.5 mL per plate |
| Pack size | 10 plates per sleeve (as stated on label) |
| Storage | 2–8 °C, in the dark, in the original sleeve, agar side up. Do not freeze. |
| Shipping conditions | Chilled, insulated carton with coolant packs; plates separated from the coolant |
| Dispatch | Mondays, to avoid weekend transit |
| Shelf life | 6 weeks from date of manufacture; expiry stated on label |
| pH (25 °C) | 7.0 ± 0.2 |
| Appearance | Light amber, clear to slightly opalescent gel |
| Incubation | 35–37 °C, 18–24 hours, aerobic |
| Documents | TDS, SDS; batch COA on request |
How to Use
- Bring plates to room temperature. Discard any plate showing contamination, cracking, shrinkage or condensation on the agar.
- If the surface is moist, dry it with the lid ajar in a laminar flow cabinet before inoculating.
- Streak plate: inoculate with a sterile loop for isolation or purity checking.
- Spread plate: pipette 0.1 mL of culture or dilution onto the surface and spread with a sterile spreader until absorbed.
- Incubate inverted at 35–37 °C for 18–24 hours.
- Pick single colonies for subculture or screening.
On Arrival
Refrigerate on arrival. Check the sleeve for cracked, dried or contaminated plates and tell us within seven days if any are affected.
Plates are packed so they never touch the coolant, because contact freezes the gel and ruins the plate. If a carton arrives warm, refrigerate it and contact us before use.
Storage & Disposal
Store at 2–8 °C in the dark, in the original sleeve, agar side up with the lid down. Do not freeze; freezing ruptures the gel and the plate cannot be used. Used plates contain viable microorganisms. Autoclave (121 °C, at least 15 minutes) or incinerate. If neither is possible, flood plates with 5–10 % bleach, leave overnight, then discard according to local regulations.
Antibiotic Plates
LB agar plates containing ampicillin, kanamycin, chloramphenicol or another antibiotic are made to order with the antibiotic incorporated before pouring. Contact us with the antibiotic and concentration you need.
Technical Data Sheet — LB Agar (Miller) Plates
TDS-AS-704 · Rev 1.0 · November 2026Ready-to-use 90 mm LB agar plates, Miller formulation, for the routine cultivation, subculture and maintenance of Escherichia coli and other non-fastidious bacteria, and for molecular cloning workflows. For laboratory microbiological testing, quality control and research use only. Not intended for direct use in food, human or veterinary therapeutic applications, diagnosis, or consumption.
Tryptone supplies peptides and amino acids; yeast extract supplies B vitamins, nucleotides and growth factors. The medium contains no fermentable carbohydrate, so growth does not acidify the plate and inducible expression systems are unaffected. Sodium chloride at 10 g/L maintains osmotic balance in the Miller formulation. The medium is non-selective; selection of plasmid-bearing cells requires an antibiotic incorporated before the plate is poured.
| Component | g/L |
|---|---|
| Agar | 15.00 |
| Tryptone | 10.00 |
| Sodium chloride | 10.00 |
| Yeast extract | 5.00 |
| Total | 40.00 |
| Format | Ready-to-use poured plates, 90 mm, flat agar surface |
| Fill volume | 20 ± 1.5 mL per plate |
| Pack size | 10 plates per sleeve (as stated on label) |
| Storage | 2–8 °C, in the dark, in the original sleeve, agar side up. Do not freeze. |
| Shipping conditions | Chilled, insulated carton with coolant packs; plates separated from the coolant |
| Dispatch | Mondays, to avoid weekend transit |
| Shelf life | 6 weeks from date of manufacture; expiry stated on label |
| pH (25 °C) | 7.0 ± 0.2 |
| Appearance | Light amber, clear to slightly opalescent gel |
- Bring plates to room temperature. Discard any plate showing contamination, cracking, shrinkage or condensation on the agar.
- If the surface is moist, dry it with the lid ajar in a laminar flow cabinet before inoculating.
- Streak plate: inoculate with a sterile loop for isolation or purity checking.
- Spread plate: pipette 0.1 mL of culture or dilution onto the surface and spread with a sterile spreader until absorbed.
- Incubate inverted.
- Pick single colonies for subculture or screening.
Incubation: 35–37 °C, 18–24 hours, aerobic. Lower temperatures and longer incubation are used for some expression hosts and temperature-sensitive strains.
| Organism group | Typical appearance |
|---|---|
| Escherichia coli | Cream to off-white, smooth, convex colonies, 1–3 mm after 18–24 hours |
| Other non-fastidious bacteria | Growth; appearance varies by species, some pigmented |
| Yeasts and moulds | May grow on extended incubation |
Growth does not identify an organism or confirm a clone. Confirm transformants by colony PCR, restriction digestion or sequencing as appropriate.
| Organism | Strain | Inoculum (CFU) | Growth |
|---|---|---|---|
| Escherichia coli | ATCC 25922 | ≤100 | Good to luxuriant |
| Escherichia coli K-12 | ATCC 23716 | ≤100 | Good to luxuriant |
| Staphylococcus aureus | ATCC 25923 | ≤100 | Good growth |
- Non-selective. Contaminating organisms will also grow, and plasmid selection is not possible without an antibiotic.
- Antibiotics cannot be added to a plate that has already set. Antibiotic plates must be prepared with the antibiotic in the molten agar.
- Pour-plate counts are not possible with a pre-poured plate. Where your method specifies a pour-plate technique, use the dehydrated medium instead.
- Not enriched for fastidious organisms, and not suitable for strict anaerobes without an anaerobic incubation system.
- Growth rate and colony size vary between host strains.
- Growth does not confirm a clone.
Used plates contain viable microorganisms. Autoclave (121 °C, at least 15 minutes) or incinerate. If neither is possible, flood plates with 5–10 % bleach, leave overnight, then discard according to local regulations.
- Bertani G. (1951). Studies on lysogenesis. I. The mode of phage liberation by lysogenic Escherichia coli. J. Bacteriol. 62:293–300.
- Bertani G. (2004). Lysogeny at mid-twentieth century: P1, P2, and other experimental systems. J. Bacteriol. 186:595–600.
- Miller J.H. (1972). Experiments in Molecular Genetics. Cold Spring Harbor Laboratory Press.
- Green M.R., Sambrook J. (2012). Molecular Cloning: A Laboratory Manual, 4th ed. Cold Spring Harbor Laboratory Press.
- Atlas R.M. (2010). Handbook of Microbiological Media, 4th ed. CRC Press.
Safety Data Summary — LB Agar (Miller) Plates
SDS-AS-704 · Rev 1.0 · November 2026 · Full 16-section SDS available on requestNot classified as hazardous according to the criteria of the GHS (Rev. 7) as adopted under the Australian WHS Regulations. No hazard pictogram or signal word is required for unused plates.
Contains casein-derived material. People with milk protein allergy should avoid exposure.
Used plates may contain viable bacteria, including recombinant strains carrying plasmids. Where genetically modified organisms are cultured, handle and dispose of plates in accordance with your institutional biosafety approvals and the applicable Australian regulations for dealings with GMOs.
- Use good laboratory practice. Open plates only at the time of inoculation or reading.
- Wear laboratory coat and gloves; safety glasses per laboratory policy.
- Skin: Wash with soap and water.
- Eyes: Rinse with water for several minutes.
- Ingestion: Rinse mouth. Seek medical advice if you feel unwell.
- Used plates: After contact, wash thoroughly and follow your laboratory biosafety procedure.
Poisons Information Centre (Australia): 13 11 26 · Emergency: 000
Store at 2–8 °C in the dark, agar side up. Do not freeze. Used plates contain viable microorganisms. Autoclave (121 °C, at least 15 minutes) or incinerate. If neither is possible, flood plates with 5–10 % bleach, leave overnight, then discard according to local regulations.
Unused plates are not dangerous goods. Transport chilled at 2–8 °C in an insulated carton.
Quality & Certificate of Analysis
AS-704 · Batch-specific COA available on requestEach batch is manufactured in Melbourne and tested before release. A batch-specific Certificate of Analysis is available on request. Please quote the batch number printed on the sleeve.
| Test | Specification |
|---|---|
| Appearance | Light amber, clear to slightly opalescent gel, free of contamination and damage |
| Fill volume | 20 ± 1.5 mL per plate |
| pH (25 °C) | 7.0 ± 0.2 |
| Sterility | No growth after 48 h at 30–35 °C and 72 h at 20–25 °C (representative plates) |
| Growth performance | Escherichia coli ATCC 25922, Escherichia coli K-12 ATCC 23716 and Staphylococcus aureus ATCC 25923: good growth at ≤100 CFU |